TEL. & FAX +66(0)2-020-3301

ioLogik E2200 Series

Home  >   MOXA  >   Industrial Edge Connectivity  >  
Controllers & I/Os  >   Universal Controllers & I/Os

Smart Ethernet remote I/O with Click&Go Logic

Product Feature

  • Front-end intelligence with patented Click&Go control logic, up to 24 rules
  • Active communication with MX-AOPC UA Server
  • Saves time and wiring costs with peer-to-peer communications
  • Supports SNMP v1/v2c/v3
  • Friendly configuration via web browser
  • Simplifies I/O management with MXIO library for Windows or Linux
  • Wide operating temperature models available for -40 to 75°C (-40 to 167°F) environments

Introduction

Moxa’s ioLogik E2200 Series Ethernet Remote I/O is a PC-based data acquisition and control device that uses proactive, event-based reporting to control I/O devices and features the Click&Go programming interface. Unlike traditional PLCs, which are passive and must poll for data, Moxa’s ioLogik E2200 Series will, when paired with our MX-AOPC UA Server, communicate with SCADA systems using active messaging that is pushed to the server only when state changes or configured events occur. Additionally, the ioLogik E2200 features SNMP for communications and control using an NMS (Network Management System), allowing IT professionals to configure the device to push I/O status reports according to configured specifications. This report-by-exception approach, which is new to PC-based monitoring, requires far less bandwidth than traditional polling methods.

 

PC-Free Alarm and Control Intelligence

This device supports simple yet powerful Click&Go™ technology to configure event-driven reports and alarms delivered over email, TCP/UDP, or SNMP traps, giving you a powerful and effective tool for delivering timestamped status updates in real time.

With built-in Click&Go™ intelligence, this device can be configured for simple outputs paired up with simple input triggers without the need for a PC controller. This allows it to be configured to automatically report I/O events according to conditions specified by the user.

 

SNMP for Ethernet Device Management

By using SNMP, IT engineers can configure the device to deliver alarms (traps) for specific I/O events, or use it to read or write directly to the I/O registers. For the strongest security, the device features SNMPv3, with authentication and encryption. With Moxa’s SNMP-capable I/O, even IT professionals can easily integrate industrial sensors and servos over an Ethernet backbone, and with its strong network management tools, it is ideal for a wide variety of industrial applications, including environmental monitoring, telecommunications, power production and delivery, and transportation.

 

Push Technology for Events and Alarms

When used with MX-AOPC UA Server, devices can use active push communications when communicating changes in state and/or events to a SCADA system. Unlike a polling system, when using a push architecture for communications with a SCADA system, messages will only be delivered when changes in state or configured events occur, resulting in higher accuracy and lower amounts of data that need to be transferred.

Control Logic

LanguageClick&Go

Input/Output Interface

Analog Input ChannelsioLogik E2240 Series: 8
ioLogik E2242 Series: 4
Analog Output ChannelsioLogik E2240 Series: 2
Configurable DIO Channels (by
software)
ioLogik E2212 Series: 4
ioLogik E2242 Series: 12
Digital Input ChannelsioLogik E2210 Series: 12
ioLogik E2212 Series: 8
ioLogik E2214 Series: 6
Digital Output ChannelsioLogik E2210/E2212 Series: 8
ioLogik E2260/E2262 Series: 4
Relay ChannelsioLogik E2214 Series: 6
RTD ChannelsioLogik E2260 Series: 6
Thermocouple ChannelsioLogik E2262 Series: 8
ButtonsReset button
Isolation3k VDC or 2k Vrms
Rotary Switch0 to 9

Digital Inputs

ConnectorScrew-fastened Euroblock terminal
Counter Frequency900 Hz
Digital Filtering Time IntervalSoftware configurable
Dry ContactOn: short to GND
Off: open
I/O ModeDI or event counter
Points per COMioLogik E2210 Series: 12 channels
ioLogik E2212/E2242 Series: 6 channels
ioLogik E2214 Series: 3 channels
Sensor TypeioLogik E2210 Series: Dry Contact and Wet Contact (NPN)
ioLogik E2212/E2214/E2242 Series: Dry Contact and Wet Contact (NPN
or PNP)
Wet Contact (DI to GND)On: 0 to 3 VDC
Off: 10 to 30 VDC

Digital Outputs

ConnectorScrew-fastened Euroblock terminal
Current Rating200 mA per channel
I/O ModeDO or pulse output
I/O TypeSink
Over-Current Protection0.65 A per channel @ 25°C
Over-Temperature Shutdown175°C (min.)
Over-Voltage Protection45 VDC (typical)
Pulse Output Frequency1 kHz
DIO Output Leakage Current4.0 mA @ 24 VDC

Relays

ConnectorScrew-fastened Euroblock terminal
Contact Current RatingInductive load: 2 A @ 30 VDC, 250 VAC, 110 VAC
Resistive load: 5 A @ 30 VDC, 250 VAC, 110 VAC
Contact Resistance100 milli-ohms (max.)
Electrical Endurance100,000 operations @ 5 A resistive load
Mechanical Endurance1,000,000 operations
Minimum Permitted Load1 A @ 5 VDC
Pulse Output Frequency0.3 Hz at rated load
TypeForm A (N.O.) power relay
I/O ModeRelay or pulse output
NoteAmbient humidity must be non-condensing and remain between 5 and 95%.
The relays may malfunction when operating in high condensation
environments below 0°C.

Analog Inputs

AccuracyioLogik E2240/E2242:
±0.1% FSR @ 25°C
±0.3% FSR @ -10 to 60°C

ioLogik E2240-T/E2242-T:
±0.1% FSR @ 25°C
±0.3% FSR @ -10 to 60°C
±0.5% FSR @ -40 to 75°C
ConnectorScrew-fastened Euroblock terminal
I/O ModeVoltage/Current
I/O TypeDifferential
Input ImpedanceioLogik E2240 Series: 900 kilo-ohms (min.)
ioLogik E2242 Series: 200 kilo-ohms (min.)
Input RangeioLogik E2240 Series: ±150 mV, ±500 mV, ±5 V, ±10 V, 0 to 20 mA, 4 to 20
mA
ioLogik E2242 Series: ±150 mV, 0 to 150 mV, ±500 mV, 0 to 500 mV, ±5 V,
0 to 5 V, ±10 V, 0 to 10 V, 0 to 20 mA, 4 to 20 mA
Resolution16 bits
Sampling RateioLogik E2240 Series:
All Channels: 10 samples/sec for voltage; 6 samples/sec for current
Per Channel: 1.25 samples/sec for voltage; 0.75 samples/sec for current
Single channel: 1.25 samples/sec for voltage; 0.75 samples/sec for current

ioLogik E2242 Series:
All channels: 32 samples/sec
Per channel: 8 samples/sec
Single channel: 100 samples/sec
Built-in Resistor for Current Input120 ohms
Over-Voltage Protection-25 to +30 VDC (power on)
-35 to +35 VDC (power off)

Analog Outputs

AccuracyioLogik E2240:
±0.1% FSR @ 25°C
±0.3% FSR @ -10 to 60°C

ioLogik E2240-T:
±0.1% FSR @ 25°C
±0.3% FSR @ -10 to 60°C
±0.5% FSR @ -40 to 75°C
Output Range0 to 10 VDC
4 to 20 mA
Resolution12-bit
Load (Current Mode)Internal power: 250 ohms (max.)

RTDs

AccuracyioLogik E2260:
±0.1% FSR @ 25°C
±0.3% FSR @ -10 to 60°C

ioLogik E2260-T:
±0.1% FSR @ 25°C
±0.3% FSR @ -10 to 60°C
±0.5% FSR @ -40 to 75°C
ConnectorScrew-fastened Euroblock terminal
Input Connection2- or 3-wire
Input Impedance625 kilo-ohms (min.)
Sensor TypeJPT100, JPT200, JPT500 (-200 to 640°C)
JPT1000 (-200 to 350°C)
NI100, NI200, NI500 (-60 to 250°C)
NI1000 (-60 to 150°C)
NI120 (-80 to 260°C)
PT1000 (-200 to 350°C)
PT50, PT100, PT200, PT500 (-200 to 850°C)
Resistance of 310, 620, 1250, and 2200 ohms
Resolution0.1°C or 0.1 ohms
Sampling RateAll channels: 12 samples/sec
Per channel: 2 samples/sec

Thermocouples

Millivolt AccuracyioLogik E2262:
±0.1% FSR @ 25°C
±0.3% FSR @ -10 to 60°C

ioLogik E2262-T:
±0.1% FSR @ 25°C
±0.3% FSR @ -10 to 60°C
±0.5% FSR @ -40 to 75°C
TC AccuracyTypes J, T, E, S, B: ±5°C
Types K, R, N: ±8°C
CJC Accuracy±0.5°C @ 25°C
±1.5°C @ -40 to 75°C
ConnectorScrew-fastened Euroblock terminal
Input Impedance1 mega-ohms (min.)
Millivolt Type±19.532 mV
±39.062 mV
±78.126 mV
Fault and over-voltage protection: -35 to +35 VDC (power off); -25 to +30
VDC (power on)
Resolution16 bits
Sampling RateAll channels: 12 samples/sec
Per channel: 1.5 samples/sec
Sensor TypeJ, K, T, E, R, S, B, N

LED Interface

LED IndicatorsPWR, RDY, Serial, I/O Status

Ethernet Interface

10/100BaseT(X) Ports (RJ45
connector)
1
Magnetic Isolation Protection1.5 kV (built-in)

Ethernet Software Features

Configuration OptionsWeb Console (HTTP), Windows Utility (ioAdmin)
Industrial ProtocolsCGI commands, Modbus TCP Server (Slave), Moxa AOPC (Active Tag),
MXIO Library, SNMPv1 Trap, SNMPv1/v2c/v3
ManagementBOOTP, IPv4, SMTP, DHCP Client, HTTP, TCP/IP
MIBDevice Settings MIB
Time ManagementSNTP

Modbus TCP

Functions Supported1, 2, 3, 4, 5, 6, 15, 16
ModeServer (Slave)

Serial Interface

ConnectorTerminal block
Serial StandardsRS-485
No. of Ports1
Baudrate1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200 bps
ParityNone
Data Bits8
Stop Bits1
Flow ControlNone

Serial Signals

RS-485-2wData+, Data-, GND

Serial Software Features

Industrial ProtocolsModbus RTU Server (Client)

Power Parameters

Power ConnectorScrew-fastened Euroblock terminal
No. of Power Inputs1
Input Voltage12 to 36 VDC
Power ConsumptionioLogik E2210 Series: 202 mA @ 24 VDC
ioLogik E2212 Series: 136 mA @ 24 VDC
ioLogik E2214 Series: 170 mA @ 24 VDC
ioLogik E2240 Series: 198 mA @ 24 VDC
ioLogik E2242 Series: 178 mA @ 24 VDC
ioLogik E2260 Series: 95 mA @ 24 VDC
ioLogik E2262 Series: 160 mA @ 24 VDC

Physical Characteristics

Dimensions115 x 79 x 45.6 mm (4.53 x 3.11 x 1.80 in)
Weight250 g (0.55 lb)
InstallationDIN-rail mounting, Wall mounting
WiringI/O cable, 16 to 26 AWG
Power cable, 16 to 26 AWG
HousingPlastic

Environmental Limits

Operating TemperatureStandard Models: -10 to 60°C (14 to 140°F)
Wide Temp. Models: -40 to 75°C (-40 to 167°F)
Storage Temperature (package
included)
-40 to 85°C (-40 to 185°F)
Ambient Relative Humidity5 to 95% (non-condensing)
Altitude2000 m

Standards and Certifications

FreefallIEC 60068-2-32
EMCEN 61000-6-2/-6-4
SafetyUL 508
EMICISPR 32, FCC Part 15B Class A
EMSIEC 61000-4-2 ESD: Contact: 4 kV; Air: 8 kV
IEC 61000-4-3 RS: 80 MHz to 1 GHz: 10 V/m
IEC 61000-4-4 EFT: Power: 2 kV; Signal: 1 kV
IEC 61000-4-5 Surge: Power: 1 kV
IEC 61000-4-6 CS: 10 V
IEC 61000-4-8 PFMF
ShockIEC 60068-2-27
VibrationIEC 60068-2-6

Declaration

Green ProductRoHS, CRoHS, WEEE

MTBF

TimeioLogik E2210 Series: 213,673 hrs
ioLogik E2212 Series: 217,722 hrs
ioLogik E2214 Series: 307,329 hrs
ioLogik E2240 Series: 155,941 hrs
ioLogik E2242 Series: 204,391 hrs
ioLogik E2260 Series: 327,282 hrs
ioLogik E2262 Series: 341,063 hrs
StandardsTelcordia SR332

Warranty

Warranty PeriodioLogik E2214 Series: 2 years 
ioLogik E2210/E2212/E2240/E2242/E2260/E2262 Series: 5 years
DetailsSee www.moxa.com/warranty
Name Type Version Release Date
Datasheet for ioLogik E2200 Series Datasheet V1.1 06 August 2020

ioLogik E2210

Input/Output Interface 12 x DI, 8 x DO
Digital Input Sensor Type Wet Contact (NPN), Dry Contact
Analog Input Range -
Operating Temp. -10 to 60°C

ioLogik E2210-T

Input/Output Interface 12 x DI, 8 x DO
Digital Input Sensor Type Wet Contact (NPN), Dry Contact
Analog Input Range -
Operating Temp. -40 to 75°C

ioLogik E2212

Input/Output Interface 8 x DI, 4 x DIO, 8 x DO
Digital Input Sensor Type Wet Contact (NPN or PNP), Dry Contact
Analog Input Range -
Operating Temp. -10 to 60°C

ioLogik E2212-T

Input/Output Interface 8 x DI, 4 x DIO, 8 x DO
Digital Input Sensor Type Wet Contact (NPN or PNP), Dry Contact
Analog Input Range -
Operating Temp. -40 to 75°C

ioLogik E2214

Input/Output Interface 6 x DI, 6 x Relay
Digital Input Sensor Type Wet Contact (NPN or PNP), Dry Contact
Analog Input Range -
Operating Temp. -10 to 60°C

ioLogik E2214-T

Input/Output Interface 6 x DI, 6 x Relay
Digital Input Sensor Type Wet Contact (NPN or PNP), Dry Contact
Analog Input Range -
Operating Temp. -40 to 75°C

ioLogik E2240

Input/Output Interface 8 x AI, 2 x AO
Digital Input Sensor Type -
Analog Input Range ±150 mV, ±500 mV, ±5 V, ±10 V, 0-20 mA, 4-20 mA
Operating Temp. -10 to 60°C

ioLogik E2240-T

Input/Output Interface 8 x AI, 2 x AO
Digital Input Sensor Type -
Analog Input Range ±150 mV, ±500 mV, ±5 V, ±10 V, 0-20 mA, 4-20 mA
Operating Temp. -40 to 75°C

ioLogik E2242

Input/Output Interface 12 x DIO, 4 x AI
Digital Input Sensor Type Wet Contact (NPN or PNP), Dry Contact
Analog Input Range ±150 mV, 0-150 mV, ±500 mV, 0-500 mV, ±5 V, 0-5 V, ±10 V, 0-10 V, 0-20 mA, 4-20 mA
Operating Temp. -10 to 60°C

ioLogik E2242-T

Input/Output Interface 12 x DIO, 4 x AI
Digital Input Sensor Type Wet Contact (NPN or PNP), Dry Contact
Analog Input Range ±150 mV, 0-150 mV, ±500 mV, 0-500 mV, ±5 V, 0-5 V, ±10 V, 0-10 V, 0-20 mA, 4-20 mA
Operating Temp. -40 to 75°C

ioLogik E2260

Input/Output Interface 4 x DO, 6 x RTD
Digital Input Sensor Type -
Analog Input Range -
Operating Temp. -10 to 60°C

ioLogik E2260-T

Input/Output Interface 4 x DO, 6 x RTD
Digital Input Sensor Type -
Analog Input Range -
Operating Temp. -40 to 75°C

ioLogik E2262

Input/Output Interface 4 x DO, 8 x TC
Digital Input Sensor Type -
Analog Input Range -
Operating Temp. -10 to 60°C

ioLogik E2262-T

Input/Output Interface 4 x DO, 8 x TC
Digital Input Sensor Type -
Analog Input Range -
Operating Temp. -40 to 75°C

Notice: Undefined variable: rs5 in /opt/lampp/htdocs/productview.php on line 633

Notice: Trying to get property 'tab_ap' of non-object in /opt/lampp/htdocs/productview.php on line 633


Notice: Undefined variable: title_ap in /opt/lampp/htdocs/productview.php on line 638


Notice: Undefined variable: detail_ap in /opt/lampp/htdocs/productview.php on line 639

บริษัท พีที ออโตเมชั่น (ไทยแลนด์) จำกัด

  • เลขที่ 9 อาคารภคินท์ ชั้น 9 ห้องเลขที่ 901 ถนนรัชดาภิเษก แขวงดินแดง เขตดินแดง กรุงเทพฯ 10400
  • โทรและแฟกซ์ : +66(0)-2020-3000
  • อีเมล์ : [email protected]
  • Facebook : facebook.com/ptautomations

จันทร์ ถึง ศุกร์ เวลา 9.00 น. – 18.00 น.

EN
TH