TEL. & FAX +66(0)2-020-3301

MGate 5111 Series

Home  >   MOXA  >   Industrial Edge Connectivity  >  
Protocol Gateways  >   Modbus TCP Gateways

1-port Modbus/PROFINET/EtherNet/IP to PROFIBUS slave gateways

Product Feature

  • Converts Modbus, PROFINET, or EtherNet/IP to PROFIBUS
  • Supports PROFIBUS DP V0 slave
  • Supports Modbus RTU/ASCII/TCP master/client and slave/server
  • Supports EtherNet/IP Adapter
  • Supports PROFINET IO device
  • Effortless configuration via web-based wizard
  • Built-in Ethernet cascading for easy wiring
  • Embedded traffic monitoring/diagnostic information for easy troubleshooting
  • Status monitoring and fault protection for easy maintenance
  • microSD card for configuration backup/duplication and event logs
  • Supports redundant dual DC power inputs and 1 relay output
  • Serial port with 2 kV isolation protection
  • -40 to 75°C wide operating temperature models available
  • Security features based on IEC 62443

Introduction

MGate 5111 industrial Ethernet gateways convert data from Modbus RTU/ASCII/TCP, EtherNet/IP, or PROFINET to PROFIBUS protocols. All models are protected by a rugged metal housing, are DIN-rail mountable, and offer built-in serial isolation.

Modbus is one of the most widely used industrial communication protocols, and EtherNet/IP, PROFINET, and PROFIBUS are commonly used in factory automation and process automation. The MGate 5111 supports both Modbus RTU/ASCII/TCP master and slave modes, so that you can easily connect your Modbus device to PROFIBUS PLCs or DCSs, such as Siemens PLCs.

For system integration, the MGate 5111 can connect to EtherNet/IP PLC/SCADA systems, such as Rockwell Automation PLCs, to PROFIBUS PLC/DCS systems, or between a new Siemens PLC system that supports PROFINET to an existing PROFIBUS system. The MGate 5111 gateways are designed for easy configuration and quick maintenance. A handy web console can be used to implement remote maintenance tasks, and the configuration wizard UI lets you quickly set up your gateway. A comprehensive collection of troubleshooting tools reduce configuration time and system downtime. The rugged design is suitable for industrial applications, such as factory automation, power, oil and gas, water and wastewater, and other process automation industries.

 

Easy Configuration

The MGate 5111 Series has a user-friendly interface that lets you quickly set up protocol conversion routines for most applications, doing away with what were often time-consuming tasks in which users had to implement detailed parameter configurations one by one. With Quick Setup, you can easily access protocol conversion modes and finish the configuration in a few steps.

The MGate 5111 supports a web console and Telnet console for remote maintenance. Encryption communication functions, including HTTPS and SSH, are supported to provide better network security. In addition, system monitoring functions are provided to record network connections and system log events.

 

A Variety of Maintenance Functions

The MGate 5111 supports Protocol Diagnose and Traffic Monitor for easy troubleshooting, especially during the installation stage. Communication issues caused by incorrect software parameters, such as slave IDs and register addresses, or incorrect command configurations, can be fished out with Protocol Diagnose and Traffic Monitoring, which let you capture and check data to easily identify root causes.

MGate 5111 gateways also support status monitoring and fault protection functions. The status monitoring function notifies a PLC/DCS/SCADA system when a Modbus device gets disconnected or does not respond, in which case the process PLC/DCS gets the status of each end device and then issues alarms to notify operators. When a PROFIBUS cable gets disconnected, the fault protection function executes actions on end devices identified by a predefined value set by the user.

Ethernet Interface

10/100BaseT(X) Ports (RJ45
connector)
2
Auto MDI/MDI-X connection
Magnetic Isolation Protection1.5 kV (built-in)

Ethernet Software Features

Industrial ProtocolsModbus TCP Client (Master), Modbus TCP Server (Slave), PROFINET IO
Device, EtherNet/IP Adapter
Configuration OptionsWeb Console (HTTP/HTTPS), Device Search Utility (DSU), Telnet Console
ManagementARP, DHCP Client, DNS, HTTP, HTTPS, SMTP, SNMP Trap, SNMPv1/v2c/v3,
TCP/IP, Telnet, SSH, UDP, NTP Client
MIBRFC1213, RFC1317
Time ManagementNTP Client

Serial Interface

Console PortRS-232 (TxD, RxD, GND), 8-pin RJ45 (115200, n, 8, 1)
No. of Ports1
ConnectorDB9 male
Serial StandardsRS-232/422/485
Baudrate50 bps to 921.6 kbps
Data Bits7, 8
ParityNone, Even, Odd, Space, Mark
Stop Bits1, 2
Flow ControlRTS Toggle (RS-232 only), RTS/CTS
RS-485 Data Direction ControlADDC® (automatic data direction control)
Pull High/Low Resistor for RS-4851 kilo-ohm, 150 kilo-ohms
Terminator for RS-485120 ohms
Isolation2 kV (built-in)

Serial Signals

RS-232TxD, RxD, RTS, CTS, DTR, DSR, DCD, GND
RS-422Tx+, Tx-, Rx+, Rx-, GND
RS-485-2wData+, Data-, GND
RS-485-4wTx+, Tx-, Rx+, Rx-, GND

Serial Software Features

Configuration OptionsSerial Console
Industrial ProtocolsPROFIBUS DP-V0 Slave, Modbus RTU/ASCII Master, Modbus RTU/ASCII
Slave

Modbus RTU/ASCII

ModeMaster, Slave
Functions Supported1, 2, 3, 4, 5, 6, 15, 16, 23
Max. No. of Commands128
Input Data Size2048 bytes
Output Data Size2048 bytes

Modbus TCP

ModeClient (Master), Server (Slave)
Functions Supported1, 2, 3, 4, 5, 6, 15, 16, 23
Max. No. of Client Connections16
Max. No. of Server Connections31
Max. No. of Commands128
Input Data Size2048 bytes
Output Data Size2048 bytes

PROFIBUS Interface

Industrial ProtocolsPROFIBUS DP
No. of Ports1
ConnectorDB9 female
Baudrate9600 bps to 12 Mbps
Isolation2 kV (built-in)
SignalsPROFIBUS D+, PROFIBUS D-, RTS, Signal Common, 5V

PROFIBUS

Rotary SwitchPROFIBUS addresses 0-99 (addresses 100-125 supported through
software configuration)
ModeDP-V0 Slave
Max. No. of Master Connections1
Max. No. of PROFIBUS I/O
Modules
24
Input Data Size244 bytes
Output Data Size244 bytes

PROFINET

ModeIO Device
Max. No. of IO Controller
Connections
1 (for read/write)
Input Data Size512 bytes
Output Data Size512 bytes

EtherNet/IP

ModeAdapter
CIP Objects SupportedIdentity, Message Router, Assembly, Connection Manager, TCP/IP interface,
Ethernet link, Port
Max. No. of Scanner Connections1 (for read-only), 1 (for read/write)
Input Data Size496 bytes
Output Data Size496 bytes

Memory

microSD SlotUp to 32 GB (SD 2.0 compatible)

Power Parameters

Input Voltage12 to 48 VDC
Input Current416 mA @ 12 VDC
Power ConnectorSpring-type Euroblock terminal

Relays

Contact Current RatingResistive load: 2 A @ 30 VDC

Physical Characteristics

HousingMetal
IP RatingIP30
Dimensions45.8 x 105 x 134 mm (1.8 x 4.13 x 5.28 in)
Weight589 g (1.30 lb)

Environmental Limits

Operating TemperatureMGate 5111: 0 to 60°C (32 to 140°F)
MGate 5111-T: -40 to 75°C (-40 to 167°F)
Storage Temperature (package
included)
-40 to 85°C (-40 to 185°F)
Ambient Relative Humidity5 to 95% (non-condensing)

Standards and Certifications

SafetyEN 60950-1, UL 61010-2-201
EMCEN 61000-6-2/-6-4
EMICISPR 32, FCC Part 15B Class A
EMSIEC 61000-4-2 ESD: Contact: 8 kV; Air: 15 kV
IEC 61000-4-3 RS: 80 MHz to 1 GHz: 10 V/m
IEC 61000-4-4 EFT: Power: 4 kV; Signal: 4 kV
IEC 61000-4-5 Surge: Power: 2 kV; Signal: 2 kV
IEC 61000-4-6 CS: 150 kHz to 80 MHz: 10 V/m; Signal: 10 V/m
IEC 61000-4-8 PFMF
Hazardous LocationsATEX, Class I Division 2, IECEx
FreefallIEC 60068-2-32
ShockIEC 60068-2-27
VibrationIEC 60068-2-6, IEC 60068-2-64

MTBF

Time718,131 hrs
StandardsTelcordia SR332

Warranty

Warranty Period5 years
DetailsSee www.moxa.com/warranty
Name Type Version Release Date
Datasheet for MGate 5111 Series Datasheet V1.0 12 November 2018

MGate 5111

Operating Temp. 0 to 60°C

MGate 5111-T

Operating Temp. -40 to 75°C

Notice: Undefined variable: rs5 in /opt/lampp/htdocs/productview.php on line 633

Notice: Trying to get property 'tab_ap' of non-object in /opt/lampp/htdocs/productview.php on line 633


Notice: Undefined variable: title_ap in /opt/lampp/htdocs/productview.php on line 638


Notice: Undefined variable: detail_ap in /opt/lampp/htdocs/productview.php on line 639

บริษัท พีที ออโตเมชั่น (ไทยแลนด์) จำกัด

  • เลขที่ 9 อาคารภคินท์ ชั้น 9 ห้องเลขที่ 901 ถนนรัชดาภิเษก แขวงดินแดง เขตดินแดง กรุงเทพฯ 10400
  • โทรและแฟกซ์ : +66(0)-2020-3000
  • อีเมล์ : [email protected]
  • Facebook : facebook.com/ptautomations

จันทร์ ถึง ศุกร์ เวลา 9.00 น. – 18.00 น.

EN
TH